As a renewable heating system, this SPRSUN R32 series EVI DC Inverter Air Source Heat Pump features an output of 22kW. It adopts the Panasonic rotary compressor and significantly improves the problem of insufficient heating efficiency at low temperatures. It also features a 5-inch touch screen, offering you a convenient and all-in-one controlling experience. You may easily control the temperature and switch the modes via the colorful screen. Its maximum heating capacity can reach up to 22KW, and maximum cooling capacity reaches up to 20.1KW, providing you with a powerful system and high efficiency whether it’s for heating or cooling.
In addition, this low-temperature air source heat pump produces low noise and offers you a quiet environment, perfect for properties in cold areas or cold climates as it uses the outdoor air as its heat source in the winter and heat sink in the summer. Quote for SPRSUN EVI DC Inverter Air Source Heat Pumps now!

Technical Specifications
Model |
|
CGK050V3L |
CGK-050V3L |
CGK060V3L |
CGK-060V3L |
Power Supply / Refrigerant |
V/Hz/Ph |
220-240/50/1 – R32 |
380-420/50/3 – R32 |
220-240/50/1 – R32 |
380-420/50/3 – R32 |
Max. Heating Capacity (1) |
kW |
20 |
20 |
22 |
22 |
C.O.P (1) |
W/W |
4.75 |
4.76 |
4.62 |
4.65 |
Heating Capacity Min./Max.(1) |
kW |
9.2 |
/ |
20 |
9.2 |
/ |
20 |
10.12 |
/ |
22 |
10.12 |
/ |
22 |
Heating Power Input Min./Max.(1) |
W |
1549 |
/ |
4211 |
1546 |
/ |
4202 |
1752 |
/ |
4762 |
1741 |
/ |
4731 |
C.O.P Min./Max.(1) |
W/W |
4.75 |
/ |
5.94 |
4.76 |
/ |
5.95 |
4.62 |
/ |
5.78 |
4.65 |
/ |
5.81 |
Max. Heating Capacity(2) |
kW |
19.2 |
19.2 |
21.1 |
21.1 |
C.O.P (2) |
W/W |
3.85 |
3.81 |
3.70 |
3.60 |
Heating Capacity Min./Max.(2) |
kW |
8.83 |
/ |
19.20 |
8.83 |
/ |
19.20 |
9.72 |
/ |
21.12 |
9.72 |
/ |
21.12 |
Heating power input Min./Max.(2) |
W |
1957 |
/ |
5053 |
1953 |
/ |
5042 |
2214 |
/ |
5714 |
2199 |
/ |
5677 |
C.O.P Min./Max.(2) |
W/W |
3.80 |
/ |
4.51 |
3.81 |
/ |
4.52 |
3.70 |
/ |
4.39 |
3.72 |
/ |
4.42 |
Max. Cooling Capacity(3) |
kW |
18.2 |
18.2 |
20.1 |
20.1 |
E.E.R (3) |
W/W |
3.73 |
3.69 |
3.59 |
3.50 |
Cooling Capacity Min./Max.(3) |
kW |
8.39 |
/ |
18.24 |
8.39 |
/ |
18.24 |
9.23 |
/ |
20.06 |
9.23 |
/ |
20.06 |
Cooling Power Input Min./Max.(3) |
W |
1897 |
/ |
5783 |
1893 |
/ |
5771 |
2146 |
/ |
6540 |
2132 |
/ |
6498 |
E.E.R Min./Max.(3) |
W/W |
3.15 |
/ |
4.42 |
3.16 |
/ |
4.43 |
3.07 |
/ |
4.30 |
3.09 |
/ |
4.33 |
Max. Cooling Capacity(4) |
kW |
14.4 |
14.4 |
15.8 |
15.8 |
E.E.R(4) |
W/W |
2.80 |
2.77 |
2.69 |
2.62 |
Cooling Capacity Min./Max.(4) |
kW |
6.62 |
/ |
14.40 |
6.62 |
/ |
14.40 |
7.29 |
/ |
15.84 |
7.29 |
/ |
15.84 |
Cooling Power Input Min./Max.(4) |
W |
1702 |
/ |
5371 |
1699 |
/ |
5360 |
1925 |
/ |
6075 |
1913 |
/ |
6036 |
E.E.R Min./Max.(4) |
W/W |
2.68 |
/ |
3.89 |
2.69 |
/ |
3.90 |
2.61 |
/ |
3.79 |
2.62 |
/ |
3.81 |
Rated Current |
A |
20.1 |
8.9 |
22.8 |
10.0 |
Max Power Input |
kW |
6.1 |
6.1 |
6.9 |
6.9 |
Max Current |
A |
29.2 |
12.9 |
33.0 |
14.5 |
Fuse or circuitbreakerer |
A |
40A |
20A |
40A |
20A |
Compressor |
Type – Quantity/System |
|
Twin Rotary – 1 |
Twin Rotary – 1 |
Twin Rotary – 1 |
Twin Rotary – 1 |
Fan |
Quantity |
|
2 |
2 |
2 |
2 |
Airflow |
m3/h |
5000 |
5000 |
5500 |
5500 |
Rated power |
W |
200 |
200 |
210 |
210 |
Water Side Heat Exchanger |
Type |
|
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Water Pressure Drop |
kPa |
23 |
23 |
25 |
25 |
Piping Connection |
Inch |
G1″ |
G1″ |
G1″ |
G1″ |
Allowable Water Flow |
Min./Rated./Max. |
L/S |
0.60 |
0.96 |
1.59 |
0.60 |
0.96 |
1.59 |
0.66 |
1.05 |
1.75 |
0.66 |
1.05 |
1.75 |
Noise Level |
|
dB(A) |
61 |
61 |
62 |
62 |
Net Dimension(L×D×H) |
mm |
1110*475*1355 |
1110*475*1355 |
1110*475*1355 |
1110*475*1355 |
Packing Dimension(L×D×H) |
mm |
1200*540*1510 |
1200*540*1510 |
1200*540*1510 |
1200*540*1510 |
Net Weight |
Kg |
124 |
124 |
124 |
124 |
Gross Weight |
|
Kg |
161 |
161 |
161 |
161 |
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; |
(2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; |
(3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃; |
(4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃; |
The information in this document is just for reference. Since the continuous improvement and control in the production process, the information contained in this document may be subject to change. Please refer to the nameplate on the machine for model specifications.

The new refrigerant gas R32 helps our DC inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.


With maximum COP 5.95, our ERP A+++ R32 EVI DC inverter heat pumps charge and recirculate more efficiently than DC inverter heat pumps of other refrigerants. They consume less energy, and can therefore help families reduce energy bills.


The CAREL controller is able to record temperatures unaided using sensors that record the surrounding conditions. With the WIFI online monitoring, customers will enjoy contactless support from our customer service center no matter where they are. Our R32 EVI DC inverter heat pumps are also featured with more intelligent protections.

In addition to brushless DC inverter fans, SPRSUN R32 DC inverter heat pumps adopt reinforced sound reduction measures such as the dual shock absorption by Panasonic Compressor. The sound levels start as low as 42 dBA, making itself the quietest system in our DC inverter lineup.


The refrigerant R32 is considered to be environment friendly, but improper handling and storage might lead to potential safety issues. All of this can be avoid by using SPRSUN R32 DC inverter heat pumps, since they are designed with anti-explosion measures to guarantee the safety.

Arvustused
Tooteülevaateid veel ei ole.